Skip to content
Bouteille de gaz frigorigène R32 HFC R32 9 kg UN 3252 · 2.1

R32 Refrigerant Gas in Refillable 5, 9 and 30 kg Cylinders

New R32 refrigerant in refillable 5, 9 and 30 kg cylinders, for installing and servicing the latest air conditioners and heat pumps across the European Union. Final prices incl. VAT, with no VAT added at checkout whichever EU country you are in, shipped free within 3–5 working days once your bank transfer is received.

  • Pure HFC CH2F2
  • Safety class A2L
  • GWP 675
  • Prices incl. VAT

Choose your R32 cylinder

Cylinder size
  • Free delivery
  • Shipped within 3–5 working days once your SEPA transfer is received
  • Payment by bank transfer, final prices incl. VAT, invoice in your company name
  • Refillable cylinder included in the price, no deposit
  • Order in minutes: send your F-gas certificate after ordering

Several cylinders or regular orders? Request a quote

Need R410A? We supply it too

Order R32 in 3 steps

  1. You order onlineChoose your cylinder and enter your delivery details in 2 minutes.
  2. You pay by bank transferOur bank details and your payment reference are sent to you immediately.
  3. We shipWithin 3–5 working days of receiving your payment, with tracking.

R32 price per cylinder

The R32 price depends on the cylinder size and how many you order. Every figure below is a final price including VAT: what you see is what you pay, with no VAT, carriage or cylinder deposit added at checkout. The table also gives the price per kg for each size, so you can weigh a handy van cylinder against a 30 kg cylinder for the workshop.

Cylinder sizePrice incl. VATPrice per kg incl. VAT
R32 cylinder 5 kg€226.80€45.36
R32 cylinder 9 kg€342.00€38.00
R32 cylinder 30 kg€1,006.80€33.56

Final price incl. VAT, no VAT added. Free delivery, whatever the order amount. Prices updated on 14/11/2026.

VAT included, wherever you are in the EU

  • No VAT added at checkout, whichever EU country we deliver to.
  • No VAT number needed for VAT purposes, and nothing to self-account for in your own country.
  • Invoice in your company name: enter your company details and VAT number at checkout if you want them on the invoice.

Why is this gas usually cheaper per kg than R410A? The EU HFC phase-down caps the quantity of HFCs placed on the market in tonnes of CO₂ equivalent. With a GWP of 675, roughly a third of R410A's, each kilogram uses far less quota. The cap still tightens over time for all HFCs, so prices can move. Planning the installation season or supplying several teams? Request a quote for volume pricing.

R32 technical data

R32 is difluoromethane (CH₂F₂), a pure, single-component HFC rather than a blend. It has no temperature glide: at a given pressure it boils and condenses at one temperature, and a leak does not change the composition of what remains in the circuit.

Indicative data — always refer to the manufacturer's safety data sheet (SDS).
Chemical nameDifluoromethane, CH₂F₂
FamilyHFC (hydrofluorocarbon), pure single-component fluid
Safety class (ISO 817 / ASHRAE 34)A2L — lower toxicity, mildly flammable
Global warming potential (GWP, AR4)675
Ozone depletion potential (ODP)0
Boiling point (1.013 bar)approx. −51.7 °C
Temperature glidenone (pure fluid)
Critical temperatureapprox. 78.1 °C
Critical pressureapprox. 57.8 bar
Compatible oilPOE (polyolester)
TransportUN 3252, ADR class 2.1 (flammable gas)
CO₂ equivalent of a 9 kg cylinder6.1 t CO₂ eq

Operating pressures are close to, and slightly above, those of R410A, while compressor discharge temperatures run higher, which is why equipment is designed specifically for this fluid. Saturation pressures for each temperature are listed in the pressure-temperature chart further down this page.

The 6.1 t CO₂ eq figure for a 9 kg cylinder (9 kg × GWP 675) is the one to use when expressing a system charge in tonnes of CO₂ equivalent, the unit behind the F-gas obligations.

What is R32 used for?

R32 is now the standard in most new split air conditioners and in many heat pumps sold across Europe. Compared with R410A it offers better energy efficiency and needs a smaller charge for the same capacity. You will find it in:

  • residential and light-commercial split and multi-split air conditioners;
  • air-to-water heat pumps, including monobloc units replacing oil or gas boilers;
  • air-to-air heat pumps and small commercial systems designed for it.

Our cylinders cover commissioning, additional charge for long pipe runs, servicing and recharging after a leak repair. Only use it in equipment designed for it: the nameplate always decides.

Handling an A2L refrigerant safely

A2L means mildly flammable: hard to ignite, with a slow flame speed, but able to burn at certain concentrations in air when an ignition source is present. Equipment manufacturers allow for this with charge limits and installation rules; on site, a few precautions apply:

  • A2L-rated tools: recovery unit, vacuum pump and leak detector suitable for mildly flammable refrigerants.
  • Ventilation of the work area, especially in small rooms, basements and plant rooms.
  • No ignition sources: no naked flames, sparks or smoking near the circuit; recover the refrigerant and purge with nitrogen before brazing.
  • Follow the manufacturer's charge limits relative to room size.

Cylinders travel as a flammable gas, UN 3252, ADR class 2.1: upright and secured in the van, valve cap fitted, in a ventilated load space and out of direct sun.

Who can buy R32? EU F-gas rules

Despite its lower GWP, R32 is still a fluorinated greenhouse gas. In every EU Member State it falls under the F-gas Regulation (EU) 2024/573, which replaced Regulation (EU) No 517/2014, together with national implementing rules.

R32 for installation and servicing is sold to professionals only. The buyer must be a business holding the relevant F-gas certificate, or a distributor. Order online straight away without uploading anything: we ask for a copy of your certificate after the order, before dispatch.
  • F-gas certificate per Member State: technicians and, depending on the country, companies are certified under each Member State's national scheme; certificates issued in one EU country are recognised in the others.
  • Leak checks: required from 5 t CO₂ eq, which means from about 7.4 kg of this refrigerant in a circuit, at the frequency set by the Regulation. Many domestic splits stay below that threshold.
  • Record keeping: operators keep records for equipment subject to leak checks, and suppliers keep records of sales.
  • New equipment: restrictions on placing certain new equipment on the market are phased in by product type and GWP; check the current text before specifying a new installation.

Venting is prohibited: refrigerant must be recovered before a circuit is opened and sent to an approved recycling, reclamation or destruction channel. Local paperwork varies by country, so check your national authority's requirements.

How to charge an R32 system

Because it is a pure fluid, it can be charged as vapour or as liquid without affecting its composition, unlike blends.

  • Vapour suits small, slow top-ups; liquid suits larger charges, throttled on the low-pressure side to protect the compressor.
  • Weigh the charge with a refrigerant scale: nameplate quantity plus any additional charge per metre of pipework.
  • Pull a deep vacuum and confirm it with a micron gauge: POE oil is highly hygroscopic.
  • Use a manifold and hoses rated for the pressures involved and suitable for A2L.
  • Check superheat and subcooling against the pressure-temperature chart (bar gauge and absolute, in °C).

Topping up after a small leak is technically possible with a pure fluid, but good practice is still to find and fix the leak first.

R32 vs R410A vs R454B: which do you need?

R32 is not a drop-in replacement for R410A. A system built for R410A must be recharged with R410A, and an R32 unit only with R32.

RefrigerantGWPSafety classMain use
R32675A2LNew split air conditioners and heat pumps
R410A2,088A1Servicing the installed base
R454B466A2LSome new equipment designed for this blend

R410A is itself half difluoromethane, but its R125 content makes it non-flammable and changes its behaviour. Switching refrigerant on existing equipment is only acceptable where the manufacturer explicitly approves it.

Ordering, delivery and empty cylinders

  1. Order online: choose 5, 9 or 30 kg and the quantity; no document needed.
  2. Pay by bank transfer: you receive our SEPA details and payment reference straight away.
  3. Send your F-gas certificate after the order, before dispatch.
  4. Delivery: shipped free within 3–5 working days of receiving your transfer, by a carrier approved for flammable gases (ADR), with a tracking number by email.

Cylinders are refillable, included in the price and deposit-free: once empty, keep yours for refilling or hand it to an approved take-back channel. Disposable refrigerant cylinders are banned in the EU. For regular deliveries, contact us for a quote; more answers in the FAQ.

R32 pressure-temperature chart

Saturation pressure of R32 by temperature, in bar: the gauge value is what your manifold reads, the absolute value is what thermodynamic tables show.

TemperatureGauge pressure (bar g)Absolute pressure (bar a)
-40 °C0.761.77
-30 °C1.732.74
-20 °C3.054.06
-10 °C4.815.82
-5 °C5.876.88
0 °C7.128.13
+5 °C8.509.51
+10 °C10.0611.07
+15 °C11.8012.81
+20 °C13.7414.75
+25 °C15.8916.90
+30 °C18.2619.27
+35 °C20.8721.88
+40 °C23.7724.78
+45 °C26.9427.95
+50 °C30.4031.41
+55 °C34.1935.20
+60 °C38.3239.33

Rounded indicative values, based on saturation tables published by refrigerant manufacturers. R32 is a single-component refrigerant: no temperature glide.

Frequently asked questions about R32

Is R32 flammable?

Mildly. It is classified A2L: difficult to ignite, with a low flame speed. Work with A2L-rated tools, ventilate the area, keep ignition sources away and only use it in equipment designed for it.

Can R32 replace R410A in an existing system?

No. It is not a drop-in replacement: pressures, discharge temperatures and safety requirements differ. An R410A system must be recharged with R410A unless the manufacturer approves otherwise in writing.

How much does R32 cost per kg?

It depends on the cylinder size. The price table at the top of this page shows the final price incl. VAT and the price per kg for 5, 9 and 30 kg cylinders. The refillable cylinder is included with no deposit, and delivery is free.

Who can buy R32 in the EU?

Under Regulation (EU) 2024/573, only businesses holding the relevant F-gas certificate issued in an EU Member State, or distributors. You can order straight away: we ask for a copy of your certificate after the order, before dispatch.

Which oil does an R32 system use?

Polyolester (POE) oil, of the grade specified by the compressor manufacturer. POE is highly hygroscopic, so keep containers sealed and pull a deep vacuum before charging.

Should R32 be charged as liquid or vapour?

Either. As a pure fluid with no glide, its composition does not change. Vapour suits small top-ups; liquid suits larger charges, throttled on the low-pressure side. Always charge by weight.

What is the difference between R32, R410A and R454B?

R32 is a pure A2L HFC with a GWP of 675, used in most new splits. R410A is an A1 blend with a GWP of 2,088 for servicing existing systems. R454B is an A2L blend with a GWP of 466 used in some new equipment. They are not interchangeable.

Where can I find an R32 pressure-temperature chart?

On this page, just above the FAQ: it lists saturation pressures in bar, gauge and absolute, at each temperature in °C.

How do I pay, and how fast is delivery?

By bank transfer: you receive our SEPA details and reference as soon as you order. Once the funds arrive and your certificate is checked, the cylinder ships free within 3–5 working days by an ADR carrier, with tracking.

What do I do with the empty R32 cylinder?

It is included in the price and becomes yours, with no deposit. Keep it for refilling or hand it to an approved take-back channel. Never vent residual gas or put the cylinder in general waste.

Does an R32 system need leak checks?

Periodic leak checks apply from 5 tonnes of CO2 equivalent, which is about 7.4 kg of R32 in a circuit. Many domestic split systems stay below that threshold.

Also working with R410A?

R410A has replaced R32 in most new air conditioners and heat pumps. We supply it too, in refillable cylinders and on the same terms: payment by bank transfer, dispatch within 3–5 working days. The two refrigerants are not interchangeable: a R32 system is only recharged with R32, a R410A unit only with R410A.

See R410A

Need R32 fast?

From €226.80 incl. VAT per cylinder · shipped within 3–5 working days

Order Request a quote
From €226.80 incl. VAT
Buy